Exit door & panic hardware checklist · Atlanta & North Metro, GA
On every exit door we repair, we check that the latch catches, the bar releases with one push, and the strike, rods and closer sit in line. Panic bar repair starts at $145. Below are that checklist and Section 1010.2.8 of the 2024 International Building Code, which Georgia enforces since January 1, 2026, on when an exit door needs panic hardware, in plain words.
What the code text says
Quoted or closely paraphrased from Chapter 10 of the 2024 International Building Code, which Georgia adopted with state amendments effective January 1, 2026 (it replaced the 2018 edition). We have not reviewed Georgia's amendments for these sections. The local fire marshal may also apply the NFPA 101 Life Safety Code, and the fire marshal or building official has the final word on any door, so ask them before you change one.
Swinging doors serving a Group H occupancy, and swinging doors serving rooms or spaces with an occupant load of 50 or more in a Group A or E occupancy, "shall not be provided with a latch or lock other than panic hardware or fire exit hardware." The building official decides a building's occupancy group and occupant load.
Section 1010.2.8 lists exceptions, among them a main exit of a Group A occupancy with an occupant load of 300 or less, which may have locking devices under Section 1010.2.4, and doors with panic or fire exit hardware serving a Group A or E occupancy, which may be electrically locked under Section 1010.2.10. Your building official confirms whether one applies.
Doors serving transformer vaults, battery and energy storage rooms, modular data centers, and rooms with electrical equipment rated 800 amperes or more that contains overcurrent, switching or control devices, where the door is within 25 feet of the working space NFPA 70 requires, need panic or fire exit hardware and must swing in the direction of egress travel.
Where panic or fire exit hardware is installed, panic hardware shall be listed in accordance with UL 305, and fire exit hardware in accordance with UL 10C and UL 305. The actuating portion shall extend at least one-half of the door leaf width, and the maximum unlatching force shall not exceed 15 pounds.
Except as that section specifically permits, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Section 1010.2.3 sets operating hardware at 34 inches minimum and 48 inches maximum above the finished floor, with listed exceptions, and Section 1010.2.1 says unlatching takes no more than one motion, in a single linear or rotational direction.
Related: Panic bar repair · Fire-rated door hardware · Von Duprin exit devices · Alarmed exit doors · Door closers
How we work
We close the door several times and watch whether the latch catches the strike. Where the device has dogging, we check it holds the latch back and releases cleanly at closing time.

We check the strike is tight and in line, vertical rods are adjusted top and bottom, and the closer brings the door shut without slamming or stopping short.

We look at the outside trim and cylinder, any exit alarm on the device, and signs of wear: a loose bar, a cracked end cap, worn springs. Then you get the list and a price for anything that needs work.

Why businesses call us
We run this list on every exit door we repair, so a second fault on the same door is not missed.

How it is priced
Every price here is a starting price. We walk the exit door with the checklist at no charge and price each item before any work.
Prices
Starting prices. We confirm the final one at the door before any work.
| The job | Starting at |
|---|---|
| Panic bar repair | $145 |
| Rim exit device, supplied and fitted | $495 |
| Vertical-rod exit device, supplied and fitted | $895 |
| Detex alarmed exit, service | $95 |
| Detex alarmed exit, installed | $575 |
| Door closer adjustment | $125 |
Who we work for
Questions we get
Something not covered here? Call or text (470) 375-0631 and ask the locksmith directly.
2024 IBC Section 1010.2.8, Georgia's code since January 1, 2026, covers swinging doors serving Group H occupancies, and doors serving rooms or spaces with 50 or more occupants in Group A or E occupancies: if they latch or lock, it must be panic or fire exit hardware. Your building official or fire marshal confirms whether your door is one of them.
Section 1010.2.8.3 of the 2024 IBC sets the maximum unlatching force at 15 pounds. A bar that needs more usually has a dragging door, a worn mechanism or a strike out of line, and we can repair it.
Section 1010.2.8.3 of the 2024 IBC says the actuating portion shall extend not less than one-half of the door leaf width.
The local fire marshal or building official. We repair and install the hardware; they have the final word on what the code requires for your building.
Where we work
We come to you: on-site service across the communities below.
Building just outside these towns? Call or text anyway, and we will tell you straight whether we can reach it.
Page updated November 2026
Free estimate on site
A locksmith calls you back to confirm the door, the hardware and the starting price before anyone drives out.